WindTurbine - Wind Turbine
Connection Diagram:
| VW |
| SHAFT | |
| CP | LAMBDA | ||
| Connections(4) | Position | Remark |
| VW | Left | WindSpeed |
| SHAFT | Right | |
| LAMBDA | Bottom | |
| CP | Bottom | Turbine power constant 0.1 .. 0.5 |
| Parameters(5) | Default | Remark |
| Rho | 1.2 | Air Density |
| A[m2] | 4500 | Turbine swept area [m2] |
| InitialRotorSpeed[Rad/s] | 2 | Initial speed of the turbine [Rad/s] |
| Inertia[Kgm2] | 6MEG | Inertia of the rotor [Kg m^2] |
| Friction[Nms/Rad] | 250 | Friction of the rotor [Nm / (Rad/s) ] |
| Function | ||
| Status | Standard | |
| Select from | Components\Library\GreenEnergy\Wind | |
See also
Cp1, CpHeier, DrawCp, MaximumTorque, MPPwindpower, OptimumPower, VAWT, Wind,