PFC - Limited PI controller K,tau
Connection Diagram:
| L |
| DC | ||
| N | M | |||
| Connections(37) | Position | Remark |
| N | Left | |
| M | Right | |
| L | Left | |
| DC | Right |
| Parameters(5) | Default | Remark |
| PowerFactor[0..1] | 1 | Power Factor ranging from 0 to 1 |
| Efficiency[0..100] | 95 | Efficiency of the total system |
| Vdc[V] | 500 | DC voltage level, maintained by the power factor controller. |
| InitialACVoltage[V] | 230 | Initial guess for the power factor controller, select either 230 or 120 volt. |
| Q[VAR] | 0 | Reactive Power |
| Function | PI controller where the integration I is limited between min and max Parameters are specified as the proportional gain K and time constant tau | |
| Special | The limiter is inside the integrator I and therefore has anti-windup | |
| Status | Standard | |
| Select from | Components\Library\PowerConverters\System | |
See also
ACDC1phase, ACDC3phase, ActiveFrontEnd, B6U, CurrentLimiter, CurrentLimiterBiDirectional, DC2AFE, DCAC3Phase, DCAC3PhaseGrid, DCAC3PhasePWM, DCAC3PhaseVectorControl, DCACSinglePhase50Hz, DCACSinglePhase60Hz, DCDC, DCDCControlledCurrentLimited, DCDC_Bidirectional, DCGridSinglePhase, DCGridThreePhase, DCGRIDTHREEPHASEHarmonics, GRIDCONNECTION, RotorSideConverter, RotorSideConverterPQ,